Biosensors and Nanotheranostics
Bionanotechnology, Drug Delivery, Therapeutics | online ISSN 3064-7789
175
Citations
132.9k
Views
108
Articles
REVIEWS (Open Access)
Advancing Diagnostic Accuracy: A Systematic Review of Contemporary Biosensor Technologies for Clinical Detection
Muhit Rana1, Md Shamsuddin Sultan Khan 2, Tufael 3*
Biosensors and Nanotheranostics 4 (1) 1-8 https://doi.org/10.25163/biosciences.4110524
Submitted: 29 August 2025 Revised: 19 October 2025 Accepted: 24 October 2025 Published: 26 October 2025
Abstract
Biosensor technologies have rapidly evolved, offering faster, more sensitive, and more accessible diagnostic options across clinical settings. Despite their growing promise, reported diagnostic performance varies, making it essential to consolidate evidence through systematic review and meta-analysis. This study synthesizes findings from peer-reviewed publications evaluating diagnostic biosensors used for disease detection, focusing on sensitivity, specificity, response time, and practical applicability. Following PRISMA guidelines, PubMed, Scopus, and Web of Science were searched for studies published between 2000 and 2025. Eligible studies included clinical or laboratory-validated biosensors with extractable diagnostic accuracy data. A random-effects meta-analysis was conducted to estimate pooled sensitivity and specificity, while funnel plots and Egger’s test examined publication bias. Across the included studies, biosensors demonstrated consistently high diagnostic performance, with pooled sensitivity and specificity exceeding conventional laboratory assays in many cases. Forest plots revealed low between-study heterogeneity for sensitivity but moderate heterogeneity for specificity, likely reflecting differences in biosensor platforms, biorecognition elements, and target analytes. Funnel plot symmetry suggested minimal publication bias. The findings support the growing reliability of biosensors for rapid, point-of-care applications. Overall, this review highlights how biosensors are reshaping diagnostic workflows by combining speed, portability, and analytical accuracy. The evidence reinforces their potential to bridge diagnostic gaps in low-resource and high-throughput environments. Continued research is needed to standardize validation protocols and accelerate translation from laboratory prototypes to clinical implementation.
Keywords: Biosensors; Diagnostic accuracy; Sensitivity; Specificity; Systematic review; Meta-analysis; Clinical diagnostics
References
Amin, R. B., Setu, S. N., Mia, R. (2025). "Advances in CAR T-Cell Engineering and Redirected Immune Effector Cells for Enhanced Solid Tumor Immunotherapy: A Systematic Review", Journal of Precision Biosciences, 7(1), 1-8, 10540. https://doi.org/10.25163/biosciences.7110540
Asaduzzaman, M., Zahed, M. A., Sharifuzzaman, M., Reza, M. S., Hui, X., Sharma, S., Shin, Y. D., Park, C., & Park, J. Y. (2022). A hybridized nano-porous carbon reinforced 3D graphene-based epidermal patch for precise sweat glucose and lactate analysis. Biosensors and Bioelectronics, 219, 114846. https://doi.org/10.1016/j.bios.2022.114846
Beduk, T., Beduk, D., Hasan, M. R., Guler Celik, E., Kosel, J., Narang, J., Salama, K. N., & Timur, S. (2022). Smartphone-based multiplexed biosensing tools for health monitoring. Biosensors, 12(8), 583. https://doi.org/10.3390/bios12080583
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009). Introduction to meta-analysis. Wiley. https://doi.org/10.1002/9780470743386
Cheng, C., Li, X., Xu, G., Lu, Y., Low, S. S., Liu, G., Zhu, L., Li, C., & Liu, Q. (2021). Battery-free, wireless, and flexible electrochemical patch for in situ analysis of sweat cortisol via near field communication. Biosensors and Bioelectronics, 172, 112782. https://doi.org/10.1016/j.bios.2020.112782
Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A. L., Model, J. B., Aranyosi, A. J., et al. (2019). Soft, skin-integrated multifunctional microfluidic systems for accurate colorimetric analysis of sweat biomarkers and temperature. ACS Sensors, 4, 379–388. https://doi.org/10.1021/acssensors.8b01218
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Nakatsuka, T. (2011). Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta, 83(3), 960–965. https://doi.org/10.1016/j.talanta.2010.10.055
Chung, M., Skinner, W. H., Robert, C., Campbell, C. J., Rossi, R. M., Koutsos, V., & Radacsi, N. (2021). Fabrication of a wearable flexible sweat pH sensor based on SERS-active Au/TPU electrospun nanofibers. ACS Applied Materials & Interfaces, 13, 51504–51518. https://doi.org/10.1021/acsami.1c15238
Clark, J. L. C., & Lyons, C. (1962). Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of Sciences, 102(1), 29–45. https://doi.org/10.1111/j.1749-6632.1962.tb13623.x
Curto, V. F., Coyle, S., Byrne, R., Angelov, N., Diamond, D., & Benito-Lopez, F. (2012). Concept and development of an autonomous wearable micro-fluidic platform for real-time pH sweat analysis. Sensors and Actuators B: Chemical, 175, 263–270. https://doi.org/10.1016/j.snb.2012.02.010
DerSimonian, R., & Laird, N. (1986). Meta-analysis in clinical trials. Controlled Clinical Trials, 7(3), 177–188. https://doi.org/10.1016/0197-2456(86)90046-2
Egger, M., Davey Smith, G., Schneider, M., & Minder, C. (1997). Bias in meta-analysis detected by a simple, graphical test. BMJ, 315(7109), 629–634. https://doi.org/10.1136/bmj.315.7109.629
Falk, M., Psotta, C., Cirovic, S., & Shleev, S. (2020). Non-invasive electrochemical biosensors operating in human physiological fluids. Sensors, 20(20), 6352. https://doi.org/10.3390/s20216352
Ganguly, A., Rice, P., Lin, K. C., Muthukumar, S., & Prasad, S. (2020). A combinatorial electrochemical biosensor for sweat biomarker benchmarking. SLAS TECHNOLOGY: Translating Life Sciences Innovation, 25(1), 25-32. https://doi.org/10.1177/2472630319882003
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016). Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature, 529(7587), 509–514. https://doi.org/10.1038/nature16521
Gnanasigamani, M., Arslan, E., Soylu, Y., Kilit, B., & Chmura, P. (2025). Mapping multi-modal fatigue in elite soccer through sweat-omics perspectives: A narrative review. Biology, 14(8), 1069. https://doi.org/10.3390/biology14081069
Hashimoto, Y., Ishihara, T., Kuwabara, K., Amano, T., & Togo, H. (2022). Wearable microfluidic sensor for the simultaneous and continuous monitoring of sweat rates and electrolyte concentrations. Micromachines, 13(4), 575. https://doi.org/10.3390/mi13040575
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., & Zhang, Y. (2019). Integrated textile sensor patch for real-time and multiplex sweat analysis. Science Advances, 5, eaax0649. https://doi.org/10.1126/sciadv.aax0649
Heikenfeld, J. (2016). Non-invasive analyte access and sensing through eccrine sweat: Challenges and outlook circa 2016. Electroanalysis, 28, 1242–1249. https://doi.org/10.1002/elan.201600018
Higgins, J. P. T., Thomas, J., Chandler, J., Cumpston, M., Li, T., Page, M. J., & Welch, V. A. (2022). Cochrane handbook for systematic reviews of interventions (Version 6.3). Cochrane. http://www.training.cochrane.org/handbook
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003). Measuring inconsistency in meta-analyses. BMJ, 327(7414), 557–560. https://doi.org/10.1136/bmj.327.7414.557
Hossain, N. I., Noushin, T., & Tabassum, S. (2024). StressFit: A hybrid wearable physicochemical sensor suite for simultaneously measuring electromyogram and sweat cortisol. Scientific Reports, 14, 29667. https://doi.org/10.1038/s41598-024-81042-5
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdes-Ramirez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015). Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics. Biosensors and Bioelectronics, 74, 1061–1068. https://doi.org/10.1016/j.bios.2015.07.039
Kinnamon, D., Ghanta, R., Lin, K. C., Muthukumar, S., & Prasad, S. (2017). Portable biosensor for monitoring cortisol in low-volume perspired human sweat. Scientific Reports, 7(1), 13312. https://doi.org/10.1038/s41598-017-13684-7
Kumar, L. S., Wang, X., Hagen, J., Naik, R., Papautsky, I., & Heikenfeld, J. (2016). Label-free nano-aptasensor for interleukin-6 in protein-dilute biofluids such as sweat. Analytical Methods, 8, 3440–3444. https://doi.org/10.1039/C6AY00331A
Liu, M., Yang, M., Wang, M., Wang, H., & Cheng, J. (2022). A flexible dual-analyte electrochemical biosensor for salivary glucose and lactate detection. Biosensors, 12(4), 210. https://doi.org/10.3390/bios12040210
Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S. (2017). A new paradigm in sweat-based wearable diagnostic biosensors using room temperature ionic liquids (RTILs). Scientific Reports, 7, 1950. https://doi.org/10.1038/s41598-017-02133-0
Nan, M., Darmawan, B. A., Go, G., Zheng, S., Lee, J., Kim, S., Lee, T., Choi, E., Park, J.-O., & Bang, D. (2023). Wearable localized surface plasmon resonance-based biosensor for highly sensitive detection of cortisol in sweat. Biosensors, 13(2), 184. https://doi.org/10.3390/bios13020184
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., et al. (2021). The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ, 372, n71. https://doi.org/10.1136/bmj.n71
Qiao, Y., Qiao, L., Chen, Z., Liu, B., Gao, L., & Zhang, L. (2022). Wearable sensor for continuous sweat biomarker monitoring. Chemosensors, 10(7), 273. https://doi.org/10.3390/chemosensors10070273
Sekar, M., Sriramprabha, R., Sekhar, P. K., Bhansali, S., Ponpandian, N., Pandiaraj, M., & Viswanathan, C. (2020). Review-Towards wearable sensor platforms for the electrochemical detection of cortisol. Journal of The Electrochemical Society, 167, 067508. https://doi.org/10.1149/1945-7111/ab7e24
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021). Wearable biosensors: An alternative and practical approach in healthcare and disease monitoring. Molecules, 26(3), 748. https://doi.org/10.3390/molecules26030748
Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W. (2020). Wireless battery-free wearable sweat sensor powered by human motion. Science Advances, 6, eaay9842. https://doi.org/10.1126/sciadv.aay9842
Spehar-Délèze, A.-M., Anastasova, S., & Vadgama, P. (2021). Monitoring of lactate in interstitial fluid, saliva and sweat by electrochemical biosensor: The uncertainties of biological interpretation. Chemosensors, 9(8), 195. https://doi.org/10.3390/chemosensors9080195
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020). Investigation of cortisol dynamics in human sweat using a graphene-based wireless M-health system. Matter, 2(4), 921–937. https://doi.org/10.1016/j.matt.2020.01.021
Wang, B., Zhao, C., Wang, Z., Yang, K. A., Cheng, X., Liu, W., Yu, W., Lin, S., Zhao, Y., Cheung, Y., et al. (2022). Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring. Science Advances, 8(12), eabk0967. https://doi.org/10.1126/sciadv.abk0967
Weng, X., Fu, Z., Zhang, C., Jiang, W., & Jiang, H. (2022). A portable 3D microfluidic origami biosensor for cortisol detection in human sweat. Analytical Chemistry, 94(9), 3526–3534. https://doi.org/10.1021/acs.analchem.1c04508
Windmiller, J. R., & Wang, J. (2013). Wearable electrochemical sensors and biosensors: A review. Electroanalysis, 25(1), 29–46. https://doi.org/10.1002/elan.201200349
Wu, T., & Liu, G. (2025). Non-invasive wearables in inflammation monitoring: From biomarkers to biosensors. Biosensors, 15(6), 351. https://doi.org/10.3390/bios15060351
Xu, J., Fang, Y., & Chen, J. (2021). Wearable biosensors for non-invasive sweat diagnostics. Biosensors, 11(8), 245. https://doi.org/10.3390/bios11080245
Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2024). Advances in non-electrochemical sensing of human sweat biomarkers: From sweat sampling to signal reading. Biosensors, 14(1), 17. https://doi.org/10.3390/bios14010017
Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lahdesmaki, I., Otis, B. P., & Parviz, B. A. (2012). A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring. Journal of Micromechanics and Microengineering, 22(7), 075007. https://doi.org/10.1088/0960-1317/22/7/075007
Yokus, M. A., & Daniele, M. A. (2021). Integrated non-invasive biochemical and biophysical sensing systems for health and performance monitoring: A systems perspective. Biosensors and Bioelectronics, 184, 113249. https://doi.org/10.1016/j.bios.2021.113249
Yuan, X., Li, C., Yin, X., Yang, Y., Ji, B., Niu, Y., & Ren, L. (2023a). Epidermal wearable biosensors for monitoring biomarkers of chronic disease in sweat. Biosensors, 13(3), 313. https://doi.org/10.3390/bios13030313
Yuan, X., Ouaskioud, O., Yin, X., Li, C., Ma, P., Yang, Y., Yang, P.-F., Xie, L., & Ren, L. (2023b). Epidermal wearable biosensors for continuous monitoring of biomarkers in interstitial fluid. Micromachines, 14(7), 1452. https://doi.org/10.3390/mi14071452
Zamkah, A., Hui, T., Andrews, S., Dey, N., Shi, F., & Sherratt, R. S. (2020). Identification of suitable biomarkers for stress and emotion detection for future personal affective wearable sensors. Biosensors, 10(4), 40. https://doi.org/10.3390/bios10040040
Zhang, Y., Hu, Y., Jiang, N., & Yetisen, A. K. (2022). Wearable artificial intelligence biosensor networks. Biosensors and Bioelectronics, 219, 114825. https://doi.org/10.1016/j.bios.2022.114825
Recommended articles
CRISPR-Cas13 Paper Biosensors for Point-of-Care Genotyping of Thalassemia Mutations: Mechanisms, Isothermal Coupling, and Translational Readiness
Ubiquitin-Proteasome Dysfunction in Huntington's Disease and Its Mechanistic Insights and Druggable Targets Across the Proteostasis Network
Article metrics
View details
0
Downloads
0
Citations
431
Views
0
Save
Save
0
Citation
Citation
431
View
View
0
Share
Share