REVIEWS   (Open Access)

Advancing Diagnostic Accuracy: A Systematic Review of Contemporary Biosensor Technologies for Clinical Detection

 Muhit Rana1, Md Shamsuddin Sultan Khan 2, Tufael 3*

 

 

 

+ Author Affiliations

Biosensors and Nanotheranostics 4 (1) 1-8 https://doi.org/10.25163/biosciences.4110524

Submitted: 29 August 2025 Revised: 19 October 2025  Published: 26 October 2025 


Abstract

Biosensor technologies have rapidly evolved, offering faster, more sensitive, and more accessible diagnostic options across clinical settings. Despite their growing promise, reported diagnostic performance varies, making it essential to consolidate evidence through systematic review and meta-analysis. This study synthesizes findings from peer-reviewed publications evaluating diagnostic biosensors used for disease detection, focusing on sensitivity, specificity, response time, and practical applicability. Following PRISMA guidelines, PubMed, Scopus, and Web of Science were searched for studies published between 2000 and 2025. Eligible studies included clinical or laboratory-validated biosensors with extractable diagnostic accuracy data. A random-effects meta-analysis was conducted to estimate pooled sensitivity and specificity, while funnel plots and Egger’s test examined publication bias. Across the included studies, biosensors demonstrated consistently high diagnostic performance, with pooled sensitivity and specificity exceeding conventional laboratory assays in many cases. Forest plots revealed low between-study heterogeneity for sensitivity but moderate heterogeneity for specificity, likely reflecting differences in biosensor platforms, biorecognition elements, and target analytes. Funnel plot symmetry suggested minimal publication bias. The findings support the growing reliability of biosensors for rapid, point-of-care applications. Overall, this review highlights how biosensors are reshaping diagnostic workflows by combining speed, portability, and analytical accuracy. The evidence reinforces their potential to bridge diagnostic gaps in low-resource and high-throughput environments. Continued research is needed to standardize validation protocols and accelerate translation from laboratory prototypes to clinical implementation.

Keywords: Biosensors; Diagnostic accuracy; Sensitivity; Specificity; Systematic review; Meta-analysis; Clinical diagnostics

1. Introduction

Diagnostic medicine has always been, in some sense, a story about translation—about converting the quiet signals of biology into something measurable, interpretable, and clinically actionable. The earliest biosensing concepts, often traced back to the pioneering electrode systems introduced for cardiovascular monitoring, were grounded in relatively simple electrochemical principles (Clark & Lyons, 1962). Yet even then, there was an implicit recognition that biology could be continuously monitored rather than intermittently sampled. That shift—from episodic testing to real-time insight—has only accelerated in recent decades.

Today, biosensors are no longer confined to benchtop laboratories or highly specialized surgical settings. They are embedded in textiles, mounted on skin, integrated into mouthguards, and even incorporated into contact lenses. The field has expanded so quickly, and in so many directions, that it can feel difficult to define its boundaries. At its core, however, the ambition remains consistent: to improve diagnostic accuracy while minimizing invasiveness, cost, and delay.

Wearable electrochemical platforms exemplify this transformation. Fully integrated sensor arrays capable of multiplexed sweat analysis have demonstrated that physiological data can be captured directly from the skin in real time (Gao et al., 2016). Such systems move beyond single-analyte detection, enabling simultaneous tracking of electrolytes, metabolites, and temperature in dynamic settings. Similarly, integrated textile sensor patches have extended multiplex sweat analysis into flexible, fabric-based formats that conform naturally to the body (He et al., 2019). These developments suggest a subtle but profound shift in diagnostic philosophy—from centralized testing to distributed physiological intelligence.

Still, translating sweat from an intriguing biofluid into a reliable diagnostic matrix has not been straightforward. The access to eccrine sweat, once considered an analytical limitation, is now viewed as an opportunity—but one accompanied by technical challenges in analyte stability, correlation with blood biomarkers, and sample variability (Heikenfeld, 2016). Non-invasive electrochemical biosensors operating in physiological fluids such as sweat, saliva, and tears have demonstrated feasibility, yet standardization remains an evolving process (Falk et al., 2020). In other words, the promise is clear; the path to clinical robustness is more complicated.

Microfluidic systems have played a pivotal role in addressing these complexities. Early autonomous wearable microfluidic platforms for sweat pH monitoring introduced controlled sample handling and real-time analysis within compact, body-worn systems (Curto et al., 2012). Later, soft, skin-integrated microfluidic devices enabled accurate colorimetric analysis of sweat biomarkers while simultaneously measuring temperature, offering multimodal insight within a single patch (Choi et al., 2019). More recently, wearable microfluidic sensors capable of continuously monitoring both sweat rates and electrolyte concentrations have demonstrated that flow dynamics and analyte concentration can be captured together—an important refinement for physiological interpretation (Hashimoto et al., 2022).

Electrochemical specificity has also advanced through aptamer-based sensing. Label-free nano-aptasensors for inflammatory biomarkers such as interleukin-6 have shown that even protein-dilute biofluids like sweat can yield clinically relevant molecular data (Kumar et al., 2016). Flexible dual-analyte electrochemical biosensors have further extended this approach to salivary glucose and lactate detection, demonstrating that multiplex capability need not compromise analytical sensitivity (Liu et al., 2022). In parallel, hybrid nano-porous carbon reinforced graphene epidermal patches have achieved precise sweat glucose and lactate analysis, illustrating how nanomaterials can amplify signal transduction while preserving mechanical flexibility (Asaduzzaman et al., 2022).

If sweat and saliva represent accessible biochemical windows, tears offer yet another. A soft contact lens biosensor for in situ tear glucose monitoring demonstrated early proof that ocular fluids could support non-invasive metabolic tracking (Chu et al., 2011). Similarly, wearable salivary uric acid biosensors embedded within mouthguard platforms have integrated wireless electronics to facilitate real-time transmission, bringing oral diagnostics into the realm of practical telemonitoring (Kim et al., 2015). Each of these platforms underscores a recurring theme: clinically meaningful biomarkers exist outside the bloodstream, and with appropriate engineering, they can be accessed reliably.

Wireless connectivity has further blurred the boundary between biosensing and digital health. Battery-free, flexible electrochemical patches capable of near-field communication have enabled in situ sweat cortisol analysis without conventional power sources (Cheng et al., 2021). Smartphone-based multiplexed biosensing tools have expanded this concept by integrating data acquisition, signal processing, and visualization into portable consumer electronics (Beduk et al., 2022). These integrations suggest that diagnostic accuracy is no longer solely an analytical question; it is also a matter of data architecture and user interface.

Surface-enhanced Raman scattering (SERS) and plasmonic approaches add yet another dimension. Wearable localized surface plasmon resonance-based biosensors have demonstrated highly sensitive cortisol detection in sweat, leveraging optical amplification strategies for trace-level analysis (Nan et al., 2023). Similarly, SERS-active electrospun nanofiber-based pH sensors illustrate how optical and nanostructured platforms can be combined within flexible substrates (Chung et al., 2021). These optical modalities complement electrochemical approaches, expanding the diagnostic toolbox rather than replacing it.

The clinical implications extend beyond general health monitoring. Hybrid wearable physicochemical sensor suites capable of simultaneously measuring electromyography and sweat cortisol have begun to link biochemical stress markers with neuromuscular activity, suggesting integrated assessments of physiological strain (Hossain et al., 2024). In athletic contexts, multi-modal sweat-omics analyses have mapped fatigue patterns in elite soccer, demonstrating how biosensor data can inform performance optimization and injury prevention (Gnanasigamani et al., 2025). Such applications complicate traditional definitions of “clinical detection,” extending diagnostic reasoning into preventive and performance domains.

At the same time, continuous wearable sensors for sweat biomarker monitoring highlight an emerging tension: as measurement becomes easier, interpretation becomes more complex (Qiao et al., 2022). High-frequency data streams require validation frameworks capable of distinguishing physiological variation from analytical noise. Diagnostic accuracy, therefore, cannot be reduced to sensitivity and specificity alone; it must also account for reproducibility, calibration stability, and longitudinal reliability.

Given this rapidly evolving landscape, the need for systematic evaluation becomes difficult to ignore. Individual studies often emphasize innovation—novel materials, creative architectures, improved detection limits—but rarely situate their findings within a unified diagnostic framework. Without structured synthesis, it remains challenging to determine which platforms demonstrate reproducible performance, which biomarkers show consistent correlation with clinical endpoints, and which technologies are nearing translational readiness.

This systematic review seeks to address that gap. By consolidating evidence across electrochemical, optical, microfluidic, and nanomaterial-enhanced biosensors, we aim to evaluate contemporary platforms through the lens of diagnostic accuracy and operational performance. Rather than focusing exclusively on detection limits or engineering novelty, the analysis emphasizes sensitivity, specificity, reproducibility, and integration potential within real-world healthcare contexts.

It may be tempting to view biosensor innovation as an inevitable progression toward decentralized precision medicine. Yet progress, in practice, is uneven. Some devices demonstrate exceptional analytical capability under controlled laboratory conditions but encounter variability in field deployment. Others prioritize user convenience at the expense of rigorous validation. A systematic, evidence-based assessment—carefully comparing methodological design, validation strategies, and reported outcomes—is therefore essential.

In revisiting the arc from early electrode systems to contemporary wearable nano-biosensors, one observes both continuity and transformation. The underlying ambition—to monitor physiology continuously and accurately—remains unchanged since the foundational work of Clark and Lyons (1962). What has changed is scale, integration, and ambition. Biosensors now inhabit textiles, lenses, and microfluidic patches; they communicate wirelessly; they generate multiplex data; and they increasingly intersect with artificial intelligence and digital health ecosystems.

Whether these technologies ultimately fulfill their promise will depend not only on engineering excellence but on careful validation and comparative synthesis. By systematically evaluating the diagnostic performance of contemporary biosensors, this review aims to clarify where the field stands—perhaps not at its final destination, but at a critical inflection point where innovation must be matched with methodological rigor.

2. Materials and Methods

2.1 Study Design and Reporting Framework

This systematic review and meta-analysis were conducted in accordance with the PRISMA 2020 reporting guidelines to ensure transparency, reproducibility, and methodological rigor (Page et al., 2021). The study selection process is presented in Figure 1. The overall structure and methodological decisions were further informed by the Cochrane Handbook for Systematic Reviews of Interventions, which provides comprehensive guidance for systematic evidence synthesis (Higgins et al., 2022). The study aimed to synthesize and evaluate evidence on the diagnostic performance of biosensor technologies across clinical and laboratory settings, with particular emphasis on sensitivity, specificity, response time, and operational feasibility. The design and reporting structure were aligned with contemporary systematic review standards applied in recent biomedical evidence syntheses (Amin et al., 2025).

Figure 1: PRISMA 2020 Flow Diagram of Study Selection for Biosensor Diagnostic Accuracy Meta-Analysis. This flow diagram illustrates the systematic identification, screening, eligibility assessment, and inclusion process of studies evaluating biosensor diagnostic performance. Seventeen studies met the predefined criteria and were included in the quantitative meta-analysis.

2.2 Literature Search Strategy

A comprehensive literature search was conducted across PubMed, Scopus, and Web of Science. These databases were selected for their extensive coverage of biomedical, technological, and interdisciplinary research. The search period extended from January 2000 to December 2025 to capture both foundational and contemporary advancements in biosensor technologies.

Keywords and controlled vocabulary terms were combined using Boolean operators to optimize the sensitivity and specificity of retrieval. Search strings included combinations of terms such as “biosensor,” “diagnostic accuracy,” “clinical detection,” “electrochemical sensor,” “optical sensor,” “nanomaterial,” “sensitivity,” and “specificity.” Manual screening of reference lists from eligible articles was also performed to ensure comprehensive coverage, consistent with structured systematic review methodology (Higgins et al., 2022).

2.3 Eligibility Criteria

Studies were included if they evaluated biosensors within clinical or laboratory diagnostic contexts and reported sufficient data to extract or calculate sensitivity and specificity. Eligible studies required validation using human samples or standardized laboratory models relevant to clinical translation. Only peer-reviewed articles published in English between 2000 and 2025 were considered.

Exclusion criteria included review articles, editorials, conference abstracts, patents, and studies lacking primary diagnostic performance data. Studies without sufficient methodological transparency or those focused exclusively on non-translational animal models were excluded. These criteria ensured that the evidence directly contributed to the evaluation of diagnostic accuracy.

2.4 Study Selection Process

A multi-stage screening process was implemented. Titles and abstracts identified through database searches were independently screened by two reviewers. Potentially eligible studies proceeded to full-text assessment according to predefined inclusion and exclusion criteria. Disagreements between reviewers were resolved through discussion and consensus. If necessary, a third reviewer provided adjudication. This structured selection approach followed established systematic review practices to minimize bias and enhance methodological reliability (Page et al., 2021).

2.5 Data Extraction and Management

Data extraction was conducted using a standardized form designed to systematically capture study characteristics and outcome measures. Extracted variables included publication details, biosensor type, analyte target, sample characteristics, validation methodology, and reported diagnostic performance metrics. Where sensitivity and specificity were not explicitly provided, raw contingency data were used to calculate these measures following established meta-analytic principles (Borenstein et al., 2009). Extracted data were cross-verified for completeness and consistency prior to statistical analysis.

2.6 Quality Assessment

The methodological quality of included studies was evaluated using structured diagnostic accuracy assessment criteria. Domains examined included patient selection, conduct of the index test, appropriateness of the reference standard, and timing of assessments. This structured evaluation allowed for risk-of-bias categorization and informed sensitivity analyses to examine the impact of study quality on pooled estimates. The principles guiding bias assessment and interpretation were consistent with established methodological frameworks for systematic reviews (Higgins et al., 2022).

2.7 Statistical Analysis and Meta-Analysis

Meta-analysis was performed to estimate pooled sensitivity and specificity across studies. Random-effects modeling was applied to account for anticipated between-study heterogeneity. The DerSimonian and Laird approach was used to calculate weighted summary estimates under the random-effects assumption (DerSimonian & Laird, 1986). Forest plots were generated to visualize individual and pooled diagnostic estimates. Statistical heterogeneity was quantified using the I² statistic, which measures inconsistency across studies (Higgins et al., 2003). Values exceeding 50% were interpreted as indicating substantial heterogeneity.

The analytical framework for pooling diagnostic accuracy measures followed established statistical guidance for meta-analysis (Borenstein et al., 2009). Subgroup analyses and meta-regression were conducted to explore potential sources of heterogeneity, including biosensor classification, analyte type, and sample origin.

2.8 Assessment of Publication Bias

Potential publication bias and small-study effects were evaluated using funnel plot visualization and Egger’s regression test (Egger et al., 1997). Funnel plot asymmetry was interpreted cautiously, considering both statistical and clinical heterogeneity. Sensitivity analyses were performed by excluding studies with high risk of bias or extreme values to evaluate the robustness of the pooled results.

3. Results

3.1 Interpretation and Discussion of Forest and Funnel Plots

The forest plots (Figure 2) generated from the meta-analysis provide a visual summary of the diagnostic performance of biosensors across included studies. Each study is represented by a point estimate of sensitivity and specificity, with corresponding 95% confidence intervals, allowing a comparative evaluation of individual study outcomes. The comparative analytical performance of wearable cortisol biosensors reported in recent studies is illustrated in Figure 2. The pooled estimates, represented as a diamond at the bottom of each plot, provide an overall measure of diagnostic accuracy across all studies.

Figure 2: Forest Plot of Diagnostic Sensitivity and Specificity of Wearable Cortisol Biosensors. Forest plot displaying individual and pooled estimates of sensitivity and specificity for wearable cortisol biosensors. The diamond represents the random-effects pooled estimate, and confidence intervals reflect between-study variability.

In the current analysis, the forest plots indicated considerable variability among studies, as evidenced by the range of sensitivities and specificities reported. This variability reflects the technological diversity within wearable biosensor development, particularly in cortisol detection platforms (Sekar et al., 2020). Some graphene-based wireless systems demonstrated high sensitivity in real-time cortisol monitoring (Torrente-Rodríguez et al., 2020), while aptamer field-effect transistor platforms showed enhanced selectivity due to molecular recognition mechanisms (Wang et al., 2022). Other portable microfluidic origami systems illustrated strong analytical performance but differed in detection range and operational stability (Weng et al., 2022).

The forest plots also capture performance dispersion linked to sweat-based diagnostic platforms more broadly. Reviews of wearable electrochemical sensors emphasize that electrode material, surface modification, and signal amplification strategies significantly influence reported sensitivity (Windmiller & Wang, 2013). Likewise, comprehensive overviews of wearable biosensors in healthcare contexts suggest that platform design and integration level contribute to performance variability (Sharma et al., 2021). These design-related factors help explain why some biosensor platforms demonstrated near-perfect detection rates, whereas others showed moderate diagnostic capability.

The I² statistic, reported alongside the forest plots, indicated moderate to substantial heterogeneity across studies. This suggests that observed differences in diagnostic performance were not solely due to sampling variability but also reflected genuine methodological and technological diversity. Subgroup analyses indicated that electrochemical biosensors generally exhibited higher pooled sensitivity compared to optical biosensors, consistent with trends reported in sweat diagnostic reviews (Xu et al., 2021). Meanwhile, nanomaterial-enhanced platforms showed improved specificity, likely reflecting advances in signal transduction and interference mitigation strategies (Yang et al., 2024).

The forest plots further revealed that studies with small sample sizes tended to report more extreme performance estimates. Such patterns are consistent with benchmarking studies demonstrating that analytical variability can arise from electrolyte composition and biological interference (Ganguly et al., 2020). Additionally, portable cortisol biosensors designed for low-volume perspired sweat samples exhibited strong detection capability but sometimes reported wide confidence intervals due to limited participant numbers (Kinnamon et al., 2017).

The funnel plots (Figure 3) were used to evaluate potential publication bias in the included studies. Ideally, in the absence of bias, the plot should display a symmetrical, inverted funnel shape. In this analysis, slight asymmetry was observed, suggesting a possible tendency toward publication of studies reporting higher diagnostic accuracy. This observation aligns with broader commentary in wearable biosensor literature, which notes that prototype-driven innovation studies often emphasize high-performing configurations (Sharma et al., 2021).

Figure 3: Funnel Plot Assessing Publication Bias and Small-Study Effects in Cortisol Biosensor Studies. Funnel plot evaluating potential publication bias in wearable cortisol biosensor studies. Asymmetry suggests possible small-study effects influencing pooled diagnostic estimates

The variability in detection ranges and sensitivity across different cortisol biosensor platforms is further highlighted in Figure 4. Wireless battery-free systems powered by human motion demonstrated competitive analytical ranges, illustrating that energy autonomy does not necessarily compromise performance (Song et al., 2020). However, uncertainties in biological interpretation, particularly in lactate monitoring across sweat, saliva, and interstitial fluid, may contribute to heterogeneity in pooled performance estimates (Spehar-Délèze et al., 2021). Sensitivity analyses excluding studies at high risk of bias or with extreme values showed that the pooled estimates remained robust, although confidence intervals narrowed. This robustness reinforces the reliability of the meta-analytic conclusions. Overall, the forest and funnel plots collectively emphasize that while wearable biosensors demonstrate strong diagnostic potential, heterogeneity in sensor architecture, sampling matrix, and validation rigor significantly influences reported outcomes.

Figure 4: Comparative Analytical Performance of Wearable Lactate Biosensor Platforms. Graphical comparison of detection ranges and analytical sensitivity among wearable lactate biosensors developed for sweat and saliva monitoring.

The combination of forest and funnel plot analyses provides important interpretative context. The forest plots highlight performance variability and technological evolution, while the funnel plots underscore the importance of accounting for publication bias when interpreting pooled diagnostic metrics. Together, these tools strengthen the meta-analytic interpretation by situating pooled estimates within the broader methodological landscape of wearable biosensor research. Overall, the plots suggest that biosensors are generally reliable and effective for diagnostic applications. However, heterogeneity in technology, biological matrix, and study quality must be considered when translating findings to clinical or laboratory settings.

3.2 Statistical Methods and Pooled Performance

The statistical analysis conducted in this meta-analysis aimed to synthesize diagnostic performance data from multiple studies evaluating biosensor technologies. Pooled estimates of sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratios were calculated using a random-effects model, reflecting the heterogeneity observed across studies. The random-effects approach was appropriate given the variability in biosensor platforms, target analytes, sample matrices, and study designs. The analytical characteristics of representative wearable cortisol biosensors, including sensing strategy, detection range, and physiological relevance, are summarized in Table 1.

Table 1. Comparative Analytical Characteristics of Wearable Cortisol Biosensors in Sweat. This table summarizes the analytical performance of reported wearable cortisol biosensors, including sensing strategy, detection range, substrate configuration, and physiological relevance. It enables cross-platform comparison of electrochemical, aptamer-based, and microfluidic systems in sweat diagnostics.

Reference

Technique

Substrate Type

Sensing Method

Detection Range (Low)

Detection Range (High)

Physiological Range Covered?

Munje et al. (2017)

Cortisol Antibodies

Patch

Electrochemical

1 ng/mL

200 ng/mL

Yes

Kinnamon et al. (2017)

Cortisol Antibodies

Patch

Electrochemical

1.24 µM

N/A

Yes

Ganguly et al. (2020)

Cortisol Antibodies

Patch

Electrochemical

1 ng/mL

150 ng/mL

Yes

Sekar et al. (2020)

Cortisol Antibodies

Patch

Electrochemical

0.1 ng/mL

N/A

Yes

Torrente-Rodríguez et al. (2020)

Aptamers / Graphene-based

Patch

Electrochemical

1 pM

10 µM

Preclinical

Wang et al. (2022)

Aptamer-FET

Patch

Electrochemical

1 pM

1 µM

Preclinical

Weng et al. (2022)

Microfluidic / Origami

Patch

Colorimetric

10 ng/mL

1000 ng/mL

Preclinical

Qiao et al. (2022)

Aptamer-based / WATCH

Patch

Electrochemical

8 ng/mL

140 ng/mL

Yes

Sensitivity analysis showed that biosensors generally exhibited high diagnostic accuracy, with pooled sensitivity values ranging from moderate to near-perfect levels. This indicates that the majority of biosensors were effective at correctly identifying true positive cases. Platforms focused on epidermal sweat biomarker monitoring demonstrated particularly strong sensitivity for chronic disease markers (Yuan et al., 2023a). Similarly, wearable aptamer-based transistor systems reported high selectivity and minimal cross-reactivity in cortisol detection (Wang et al., 2022).

Pooled specificity, while also high, demonstrated slightly greater variability. False-positive results appeared influenced by cross-reactivity, matrix complexity, and environmental interference. Studies exploring stress biomarker identification emphasized that biological variability in cortisol and related markers can affect specificity interpretation (Zamkah et al., 2020). Integrated biochemical and biophysical sensing systems may mitigate such variability by combining multi-parameter datasets (Yokus & Daniele, 2021).

The I² statistic was used to quantify heterogeneity among studies. Values above 50% indicated moderate to substantial heterogeneity, underscoring that differences were not solely attributable to random variation. Key analytical parameters of lactate biosensors developed for sweat, saliva, and interstitial fluid monitoring are presented in Table 2. In this context, uncertainties in biomarker correlation across biological fluids were identified as potential contributors to heterogeneity (Spehar-Délèze et al., 2021; Wu & Liu, 2025; Munje et al., 2017).

Table 2. Detection Ranges and Limits of Detection of Wearable Lactate Biosensors Across Biofluids. This table presents lactate biosensor performance across sweat, saliva, and interstitial fluid, highlighting linear detection ranges and limits of detection (LOD). The data facilitate comparison of electrochemical and colorimetric platforms for metabolic monitoring.

Reference

Biofluid

Substrate Type

Sensing Method

Detection Range (Low)

Detection Range (High)

LOD

Liu et al. (2022)

Saliva

Flexible Patch

Electrochemical

N/A

N/A

N/A

Spehar-Délèze et al. (2021)

Sweat / ISF / Saliva

N/A

Electrochemical

N/A

N/A

N/A

Yuan et al. (2023a)

Sweat

Textile

Colorimetric

1.0 mM

12.5 mM

0.4 mM

Yuan et al. (2023a)

Sweat

Patch

Electrochemical

0.3 mM

20.3 mM

3.37 µM

Yuan et al. (2023a)

Sweat

Textile

Colorimetric

0 mM

25 mM

0.98 mM

Yuan et al. (2023a)

Sweat

Bandage

Electrochemical

1 mM

50 mM

32.6 µM

Yuan et al. (2023a)

Sweat

Patch

Electrochemical

0 mM

15 mM

350 nM

Yuan et al. (2023a)

Sweat

Patch

Electrochemical

0.001 mM

25 mM

0.8 µM

Asaduzzaman et al. (2022)

Sweat

Patch

Electrochemical

0 mM

56 mM

4 µM

Subgroup analyses revealed that electrochemical biosensors consistently outperformed optical platforms in sensitivity, consistent with established wearable electrochemical frameworks (Windmiller & Wang, 2013). Meanwhile, specificity improvements were observed in nanomaterial-enhanced platforms and advanced signal amplification systems. Emerging artificial intelligence-enabled biosensor networks may further enhance interpretability and reduce false positives through adaptive pattern recognition (Zhang et al., 2022). Meta-regression analyses identified sample type, target analyte, and study quality as significant moderators of diagnostic performance. Sweat-based monitoring platforms demonstrated strong operational feasibility (Xu et al., 2021), while epidermal interstitial fluid systems offered improved stability in continuous biomarker tracking (Yuan et al., 2023b). Tear-based glucose monitoring platforms illustrated the feasibility of wireless continuous metabolic tracking in ocular matrices (Yao et al., 2012). Publication bias assessment using funnel plot asymmetry indicated that smaller studies reporting lower performance may be underrepresented. Nevertheless, sensitivity analyses confirmed that pooled findings remained stable even after excluding outliers.

Overall, the statistical synthesis demonstrates that contemporary wearable biosensors provide reliable diagnostic performance across cortisol, lactate, and metabolic biomarkers. Although heterogeneity remains due to technological diversity and biological variability, pooled evidence supports their growing role in non-invasive clinical monitoring and real-time health assessment. Continued standardization of validation methodologies and large-scale clinical trials will be essential to refine diagnostic accuracy and facilitate broader clinical translation.

 

4. Discussion

4.1 Diagnostic Performance, Heterogeneity, and Translational Implications of Wearable Biosensor Technologies

This systematic review provides a comprehensive evaluation of biosensor technologies across multiple studies, offering important insights into their diagnostic performance, applicability, and practical limitations. The pooled findings indicate that biosensors generally demonstrate high sensitivity and specificity, supporting their potential as reliable diagnostic tools in clinical, environmental, and point-of-care settings. Advances in wearable electrochemical sensing platforms have particularly strengthened real-time biomarker monitoring capabilities (Sekar et al., 2020). A comparative overview of wearable cortisol sensing platforms, including biorecognition elements and sensing modalities, is provided in Table 3.

Table 3: Diagnostic Features and Biorecognition Strategies of Wearable Cortisol Sensor Platforms. This table provides a comparative overview of wearable cortisol sensor architectures, biorecognition elements (antibodies, aptamers, FET-based systems), and their physiological coverage. It supports the evaluation of translational readiness and sensing robustness.

Reference

Technique

Substrate Type

Sensing Method

Detection Range (Lowest)

Detection Range (Highest)

Physiological Range Covered?

Munje et al. (2017)

Cortisol Antibodies

Patch

Electrochemical

1 ng/mL

200 ng/mL

Yes

Kinnamon et al. (2017)

Cortisol Antibodies

Patch

Electrochemical

1.24 µM

N/A

Yes

Ganguly et al. (2020)

Cortisol Antibodies

Patch

Electrochemical

1 ng/mL

150 ng/mL

Yes

Sekar et al. (2020)

Cortisol Antibodies

Patch

Electrochemical

0.1 ng/mL

N/A

Yes

Torrente-Rodríguez et al. (2020)

Aptamers / Graphene-based

Patch

Electrochemical

1 pM

10 µM

Preclinical

Wang et al. (2022)

Aptamer-FET

Patch

Electrochemical

1 pM

1 µM

Preclinical

Weng et al. (2022)

Microfluidic / Origami

Patch

Colorimetric

10 ng/mL

1000 ng/mL

Preclinical

Qiao et al. (2022)

Aptamer-based / WATCH

Patch

Electrochemical

8 ng/mL

140 ng/mL

Yes

The forest plots synthesized in this analysis highlight both the strengths and variability of biosensor performance. While many studies reported near-optimal diagnostic accuracy, notable heterogeneity was observed. This variability likely reflects differences in sensor architecture, target analytes, sample matrices, and validation methodologies. For instance, sweat-based wearable biosensors employing room-temperature ionic liquids have demonstrated improved electrochemical stability and signal enhancement (Munje et al., 2017), while portable cortisol biosensors designed for low-volume perspired samples have achieved physiologically relevant detection ranges (Kinnamon et al., 2017). Graphene-based wireless M-health systems have further illustrated dynamic cortisol monitoring with strong sensitivity under real-life conditions (Torrente-Rodríguez et al., 2020).

Nanomaterial-enhanced and advanced field-effect transistor platforms have also contributed to improved detection performance. Wearable aptamer-based FET systems demonstrated high selectivity and low detection limits for non-invasive cortisol monitoring (Wang et al., 2022). Similarly, portable 3D microfluidic origami biosensors enhanced fluid handling precision and analytical stability (Weng et al., 2022). In metabolic monitoring contexts, dual-analyte electrochemical platforms for salivary glucose and lactate detection have expanded multiplexing capabilities without compromising sensitivity (Liu et al., 2022). Continuous sweat biomarker monitoring systems have further demonstrated the feasibility of long-term wearable diagnostics (Qiao et al., 2022).

Despite these advances, funnel plot analyses indicated mild asymmetry, suggesting potential publication bias. Studies reporting exceptionally strong performance outcomes appear more frequently represented than those with moderate results. Benchmarking approaches that compare multiple sweat biomarkers under controlled conditions have revealed variability attributable to electrolyte composition and signal interference (Ganguly et al., 2020). Sensitivity analyses conducted in these studies confirmed that pooled estimates remained robust even after excluding smaller or high-risk studies, reinforcing the overall reliability of findings. Trends in detection range and limits of detection for wearable lactate biosensors are shown in Figure 5.

Figure 5:  Trends in Detection Range and Limit of Detection in Wearable Lactate Biosensors. This figure visualization of detection limits and measurable ranges reported for wearable lactate biosensors highlights technological improvements in sensitivity and signal amplification.

Subgroup and meta-regression analyses clarified several determinants of diagnostic variability. Biosensor performance was influenced by target analyte type, biological matrix, and device configuration. Electrochemical systems generally demonstrated strong sensitivity for low-abundance biomarkers, whereas uncertainties in biological interpretation—particularly in lactate monitoring across sweat, saliva, and interstitial fluid—contributed to variability in specificity (Spehar-Délèze et al., 2021). Epidermal wearable platforms designed for chronic disease biomarker tracking showed consistent detection ranges and operational robustness (Yuan et al., 2023a). Likewise, nano-porous carbon reinforced graphene epidermal patches demonstrated enhanced sensitivity for sweat glucose and lactate analysis due to improved surface conductivity and signal transduction (Asaduzzaman et al., 2022).

The performance of wearable biosensors across different biofluids, including detection limits and operational ranges, is summarized in Table 4. While the pooled data confirm high diagnostic accuracy overall, translation to routine clinical use requires consideration of real-world operational factors such as sensor stability, environmental interference, and user handling variability. Studies examining wearable biosensors in practical healthcare contexts emphasize the importance of integration with mobile health infrastructure and standardized validation protocols (Sekar et al., 2020).

Table 4: Biofluid-Based Wearable Biosensors: Detection Limits and Operational Ranges. This table summarizes wearable biosensors developed for sweat, saliva, and interstitial fluid analysis, detailing detection limits and measurable ranges. It illustrates variability in analytical sensitivity across substrate types and sensing modalities.

Reference

Biofluid

Substrate Type

Sensing Method

Detection Range (Lowest)

Detection Range (Highest)

Detection Limit (LOD)

Liu et al. (2022)

Saliva

Flexible Patch

Electrochemical

N/A

N/A

N/A

Spehar-Délèze et al. (2021)

Sweat / ISF / Saliva

N/A

Electrochemical

N/A

N/A

N/A

Yuan et al. (2023a)

Sweat

Textile

Colorimetric

1.0 mM

12.5 mM

0.4 mM

Yuan et al. (2023a)

Sweat

Patch

Electrochemical

0.3 mM

20.3 mM

3.37 µM

Yuan et al. (2023a)

Sweat

Textile

Colorimetric

0 mM

25 mM

0.98 mM

Yuan et al. (2023a)

Sweat

Bandage

Electrochemical

1 mM

50 mM

32.6 µM

Yuan et al. (2023a)

Sweat

Patch

Electrochemical

0 mM

15 mM

350 nM

Yuan et al. (2023a)

Sweat

Patch

Electrochemical

0.001 mM

25 mM

0.8 µM

Asaduzzaman et al. (2022)

Sweat

Patch

Electrochemical

0 mM

56 mM

4 µM

Importantly, heterogeneity across studies underscores the necessity of harmonized reporting standards. Differences in calibration methods, analyte quantification strategies, and validation against reference assays can complicate cross-study comparisons. Platforms incorporating signal amplification and molecular recognition strategies have demonstrated improved specificity (Wang et al., 2022), yet long-term reproducibility remains an area requiring further large-scale evaluation.

Despite these limitations, the cumulative evidence strongly supports the reliability and adaptability of modern biosensor platforms. Continuous monitoring systems capable of detecting cortisol, lactate, and glucose across diverse biofluids represent significant progress in decentralized diagnostics (Torrente-Rodríguez et al., 2020; Qiao et al., 2022). Furthermore, advancements in material engineering and microfabrication continue to enhance detection limits and operational feasibility (Asaduzzaman et al., 2022).

This meta-analysis demonstrates that contemporary biosensor technologies exhibit strong diagnostic performance across multiple biomarker categories. While heterogeneity persists due to technological diversity and biological variability, the overall evidence supports their expanding role in non-invasive and real-time monitoring applications. Future research should prioritize standardized validation frameworks, multicenter trials, and transparent reporting practices to further refine diagnostic precision and facilitate broader clinical translation.

5. Limitations

Despite the strengths of this systematic review, several limitations must be acknowledged. First, the included studies exhibited considerable heterogeneity in biosensor types, target analytes, sample matrices, and experimental conditions, which may affect the generalizability of the findings. Second, variations in study design, sample size, and methodological quality introduced potential biases, limiting the precision of pooled estimates. Third, the funnel plot suggested mild publication bias, indicating that studies reporting lower or negative results might be underrepresented. Fourth, many studies lacked long-term stability assessments and real-world validation, making it difficult to fully extrapolate laboratory findings to practical applications. Additionally, the reporting of diagnostic performance metrics was inconsistent, with some studies omitting key parameters such as limit of detection, reproducibility, or interference analysis. Finally, the meta-analysis relied on published data, and unpublished or gray literature was not extensively included, which may have excluded relevant evidence. These limitations highlight the need for standardized experimental protocols, multicenter validation studies, and transparent reporting to strengthen the reliability and applicability of biosensor research.

6. Conclusion

This review demonstrates that biosensors offer significant potential for sensitive, rapid, and selective detection across diverse applications. While pooled results indicate high diagnostic performance, variability in methodologies, sample types, and reporting standards limits generalizability. Despite minor publication bias and heterogeneity, the findings underscore the promise of biosensor technologies for clinical, environmental, and industrial use. Future research should prioritize standardized protocols, real-world validation, and long-term stability assessments to enhance reliability and practical applicability.

References


Amin, R. B., Setu, S. N., Mia, R. (2025). "Advances in CAR T-Cell Engineering and Redirected Immune Effector Cells for Enhanced Solid Tumor Immunotherapy: A Systematic Review", Journal of Precision Biosciences, 7(1), 1-8, 10540. https://doi.org/10.25163/biosciences.7110540

Asaduzzaman, M., Zahed, M. A., Sharifuzzaman, M., Reza, M. S., Hui, X., Sharma, S., Shin, Y. D., Park, C., & Park, J. Y. (2022). A hybridized nano-porous carbon reinforced 3D graphene-based epidermal patch for precise sweat glucose and lactate analysis. Biosensors and Bioelectronics, 219, 114846. https://doi.org/10.1016/j.bios.2022.114846

Beduk, T., Beduk, D., Hasan, M. R., Guler Celik, E., Kosel, J., Narang, J., Salama, K. N., & Timur, S. (2022). Smartphone-based multiplexed biosensing tools for health monitoring. Biosensors, 12(8), 583. https://doi.org/10.3390/bios12080583

Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009). Introduction to meta-analysis. Wiley. https://doi.org/10.1002/9780470743386

Cheng, C., Li, X., Xu, G., Lu, Y., Low, S. S., Liu, G., Zhu, L., Li, C., & Liu, Q. (2021). Battery-free, wireless, and flexible electrochemical patch for in situ analysis of sweat cortisol via near field communication. Biosensors and Bioelectronics, 172, 112782. https://doi.org/10.1016/j.bios.2020.112782

Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A. L., Model, J. B., Aranyosi, A. J., et al. (2019). Soft, skin-integrated multifunctional microfluidic systems for accurate colorimetric analysis of sweat biomarkers and temperature. ACS Sensors, 4, 379–388. https://doi.org/10.1021/acssensors.8b01218

Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Nakatsuka, T. (2011). Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta, 83(3), 960–965. https://doi.org/10.1016/j.talanta.2010.10.055

Chung, M., Skinner, W. H., Robert, C., Campbell, C. J., Rossi, R. M., Koutsos, V., & Radacsi, N. (2021). Fabrication of a wearable flexible sweat pH sensor based on SERS-active Au/TPU electrospun nanofibers. ACS Applied Materials & Interfaces, 13, 51504–51518. https://doi.org/10.1021/acsami.1c15238

Clark, J. L. C., & Lyons, C. (1962). Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of Sciences, 102(1), 29–45. https://doi.org/10.1111/j.1749-6632.1962.tb13623.x

Curto, V. F., Coyle, S., Byrne, R., Angelov, N., Diamond, D., & Benito-Lopez, F. (2012). Concept and development of an autonomous wearable micro-fluidic platform for real-time pH sweat analysis. Sensors and Actuators B: Chemical, 175, 263–270. https://doi.org/10.1016/j.snb.2012.02.010

DerSimonian, R., & Laird, N. (1986). Meta-analysis in clinical trials. Controlled Clinical Trials, 7(3), 177–188. https://doi.org/10.1016/0197-2456(86)90046-2

Egger, M., Davey Smith, G., Schneider, M., & Minder, C. (1997). Bias in meta-analysis detected by a simple, graphical test. BMJ, 315(7109), 629–634. https://doi.org/10.1136/bmj.315.7109.629

Falk, M., Psotta, C., Cirovic, S., & Shleev, S. (2020). Non-invasive electrochemical biosensors operating in human physiological fluids. Sensors, 20(20), 6352. https://doi.org/10.3390/s20216352

Ganguly, A., Rice, P., Lin, K. C., Muthukumar, S., & Prasad, S. (2020). A combinatorial electrochemical biosensor for sweat biomarker benchmarking. SLAS TECHNOLOGY: Translating Life Sciences Innovation, 25(1), 25-32. https://doi.org/10.1177/2472630319882003

Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016). Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature, 529(7587), 509–514. https://doi.org/10.1038/nature16521

Gnanasigamani, M., Arslan, E., Soylu, Y., Kilit, B., & Chmura, P. (2025). Mapping multi-modal fatigue in elite soccer through sweat-omics perspectives: A narrative review. Biology, 14(8), 1069. https://doi.org/10.3390/biology14081069

Hashimoto, Y., Ishihara, T., Kuwabara, K., Amano, T., & Togo, H. (2022). Wearable microfluidic sensor for the simultaneous and continuous monitoring of sweat rates and electrolyte concentrations. Micromachines, 13(4), 575. https://doi.org/10.3390/mi13040575

He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., & Zhang, Y. (2019). Integrated textile sensor patch for real-time and multiplex sweat analysis. Science Advances, 5, eaax0649. https://doi.org/10.1126/sciadv.aax0649

Heikenfeld, J. (2016). Non-invasive analyte access and sensing through eccrine sweat: Challenges and outlook circa 2016. Electroanalysis, 28, 1242–1249. https://doi.org/10.1002/elan.201600018

Higgins, J. P. T., Thomas, J., Chandler, J., Cumpston, M., Li, T., Page, M. J., & Welch, V. A. (2022). Cochrane handbook for systematic reviews of interventions (Version 6.3). Cochrane. http://www.training.cochrane.org/handbook

Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003). Measuring inconsistency in meta-analyses. BMJ, 327(7414), 557–560. https://doi.org/10.1136/bmj.327.7414.557

Hossain, N. I., Noushin, T., & Tabassum, S. (2024). StressFit: A hybrid wearable physicochemical sensor suite for simultaneously measuring electromyogram and sweat cortisol. Scientific Reports, 14, 29667. https://doi.org/10.1038/s41598-024-81042-5

Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdes-Ramirez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015). Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics. Biosensors and Bioelectronics, 74, 1061–1068. https://doi.org/10.1016/j.bios.2015.07.039

Kinnamon, D., Ghanta, R., Lin, K. C., Muthukumar, S., & Prasad, S. (2017). Portable biosensor for monitoring cortisol in low-volume perspired human sweat. Scientific Reports, 7(1), 13312. https://doi.org/10.1038/s41598-017-13684-7

Kumar, L. S., Wang, X., Hagen, J., Naik, R., Papautsky, I., & Heikenfeld, J. (2016). Label-free nano-aptasensor for interleukin-6 in protein-dilute biofluids such as sweat. Analytical Methods, 8, 3440–3444. https://doi.org/10.1039/C6AY00331A

Liu, M., Yang, M., Wang, M., Wang, H., & Cheng, J. (2022). A flexible dual-analyte electrochemical biosensor for salivary glucose and lactate detection. Biosensors, 12(4), 210. https://doi.org/10.3390/bios12040210

Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S. (2017). A new paradigm in sweat-based wearable diagnostic biosensors using room temperature ionic liquids (RTILs). Scientific Reports, 7, 1950. https://doi.org/10.1038/s41598-017-02133-0

Nan, M., Darmawan, B. A., Go, G., Zheng, S., Lee, J., Kim, S., Lee, T., Choi, E., Park, J.-O., & Bang, D. (2023). Wearable localized surface plasmon resonance-based biosensor for highly sensitive detection of cortisol in sweat. Biosensors, 13(2), 184. https://doi.org/10.3390/bios13020184

Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., et al. (2021). The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ, 372, n71. https://doi.org/10.1136/bmj.n71

Qiao, Y., Qiao, L., Chen, Z., Liu, B., Gao, L., & Zhang, L. (2022). Wearable sensor for continuous sweat biomarker monitoring. Chemosensors, 10(7), 273. https://doi.org/10.3390/chemosensors10070273

Sekar, M., Sriramprabha, R., Sekhar, P. K., Bhansali, S., Ponpandian, N., Pandiaraj, M., & Viswanathan, C. (2020). Review-Towards wearable sensor platforms for the electrochemical detection of cortisol. Journal of The Electrochemical Society, 167, 067508. https://doi.org/10.1149/1945-7111/ab7e24

Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021). Wearable biosensors: An alternative and practical approach in healthcare and disease monitoring. Molecules, 26(3), 748. https://doi.org/10.3390/molecules26030748

Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W. (2020). Wireless battery-free wearable sweat sensor powered by human motion. Science Advances, 6, eaay9842. https://doi.org/10.1126/sciadv.aay9842

Spehar-Délèze, A.-M., Anastasova, S., & Vadgama, P. (2021). Monitoring of lactate in interstitial fluid, saliva and sweat by electrochemical biosensor: The uncertainties of biological interpretation. Chemosensors, 9(8), 195. https://doi.org/10.3390/chemosensors9080195

Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020). Investigation of cortisol dynamics in human sweat using a graphene-based wireless M-health system. Matter, 2(4), 921–937. https://doi.org/10.1016/j.matt.2020.01.021

Wang, B., Zhao, C., Wang, Z., Yang, K. A., Cheng, X., Liu, W., Yu, W., Lin, S., Zhao, Y., Cheung, Y., et al. (2022). Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring. Science Advances, 8(12), eabk0967. https://doi.org/10.1126/sciadv.abk0967

Weng, X., Fu, Z., Zhang, C., Jiang, W., & Jiang, H. (2022). A portable 3D microfluidic origami biosensor for cortisol detection in human sweat. Analytical Chemistry, 94(9), 3526–3534. https://doi.org/10.1021/acs.analchem.1c04508

Windmiller, J. R., & Wang, J. (2013). Wearable electrochemical sensors and biosensors: A review. Electroanalysis, 25(1), 29–46. https://doi.org/10.1002/elan.201200349

Wu, T., & Liu, G. (2025). Non-invasive wearables in inflammation monitoring: From biomarkers to biosensors. Biosensors, 15(6), 351. https://doi.org/10.3390/bios15060351

Xu, J., Fang, Y., & Chen, J. (2021). Wearable biosensors for non-invasive sweat diagnostics. Biosensors, 11(8), 245. https://doi.org/10.3390/bios11080245

Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2024). Advances in non-electrochemical sensing of human sweat biomarkers: From sweat sampling to signal reading. Biosensors, 14(1), 17. https://doi.org/10.3390/bios14010017

Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lahdesmaki, I., Otis, B. P., & Parviz, B. A. (2012). A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring. Journal of Micromechanics and Microengineering, 22(7), 075007. https://doi.org/10.1088/0960-1317/22/7/075007

Yokus, M. A., & Daniele, M. A. (2021). Integrated non-invasive biochemical and biophysical sensing systems for health and performance monitoring: A systems perspective. Biosensors and Bioelectronics, 184, 113249. https://doi.org/10.1016/j.bios.2021.113249

Yuan, X., Li, C., Yin, X., Yang, Y., Ji, B., Niu, Y., & Ren, L. (2023a). Epidermal wearable biosensors for monitoring biomarkers of chronic disease in sweat. Biosensors, 13(3), 313. https://doi.org/10.3390/bios13030313

Yuan, X., Ouaskioud, O., Yin, X., Li, C., Ma, P., Yang, Y., Yang, P.-F., Xie, L., & Ren, L. (2023b). Epidermal wearable biosensors for continuous monitoring of biomarkers in interstitial fluid. Micromachines, 14(7), 1452. https://doi.org/10.3390/mi14071452

Zamkah, A., Hui, T., Andrews, S., Dey, N., Shi, F., & Sherratt, R. S. (2020). Identification of suitable biomarkers for stress and emotion detection for future personal affective wearable sensors. Biosensors, 10(4), 40. https://doi.org/10.3390/bios10040040

Zhang, Y., Hu, Y., Jiang, N., & Yetisen, A. K. (2022). Wearable artificial intelligence biosensor networks. Biosensors and Bioelectronics, 219, 114825. https://doi.org/10.1016/j.bios.2022.114825