Abstract

Glucose monitoring has evolved from a laboratory measurement into a cornerstone of modern disease management. As the global burden of diabetes continues to rise, the demand for accurate, reliable, and real-time glucose sensing technologies has intensified. This review traces the historical progression of glucose biosensors—from early enzyme electrodes in the 1960s to contemporary wearable and minimally invasive systems—while emphasizing the transformative role of metal-based nanomaterials in enhancing analytical performance. Early biosensors established the principles of enzyme-mediated electrochemical detection, yet were often limited by signal instability, restricted sensitivity, and calibration variability. The integration of metallic nanoparticles, metal oxides, and conductive nanocomposites marked a decisive technological shift. By increasing effective surface area, accelerating interfacial electron transfer, and lowering operational overpotentials, these nanostructured materials consistently improved sensitivity and detection limits across enzymatic and non-enzymatic platforms. Hybrid systems combining conductive polymers with metallic catalysts further strengthened enzyme immobilization and operational durability. Beyond analytical gains, structural innovations such as microneedle arrays, flexible hydrogels, and wearable patches demonstrate how material engineering and device architecture now work synergistically. These advances support continuous monitoring under dynamic physiological conditions, expanding glucose sensing beyond the laboratory and into daily life. Although methodological variability and inconsistent reporting complicate direct comparison across studies, a clear directional trend emerges: metal-enhanced bioelectrodes reliably strengthen electrochemical performance. Continued standardization, real-sample validation, and long-term stability testing will be essential to translate these promising technologies into routine clinical and industrial practice.

Keywords: Glucose biosensor; Metal nanoparticles; Nanostructured electrodes; Electrochemical sensing; Continuous glucose monitoring

References

Abul Rub, F., Moursy, N., Alhedeithy, N., Mohamed, J., Ifthikar, Z., Elahi, M. A., Mir, T. A., Rehman, M. U., Tariq, S., Alabudahash, M., Chinnappan, R., & Yaqinuddin, A. (2025). Modern emerging biosensing methodologies for the early diagnosis and screening of ovarian cancer. Biosensors, 15(4), 203.
https://doi.org/10.3390/bios15040203

Al-Sagur, H., Komathi, S., Khan, M. A., Gurek, A. G., & Hassan, A. (2017). A novel glucose sensor using lutetium phthalocyanine as redox mediator in reduced graphene oxide conducting polymer multifunctional hydrogel. Biosensors and Bioelectronics, 92, 638–645. https://doi.org/10.1016/j.bios.2016.10.038

American Diabetes Association. (2010). Diagnosis and classification of diabetes mellitus. Diabetes Care, 33(Suppl. 1), S62–S69. https://doi.org/10.2337/dc10-S062

Boutati, E. I., & Raptis, S. A. (2009). Self-monitoring of blood glucose as part of the integral care of type 2 diabetes. Diabetes Care, 32(Suppl. 2), S205–S210. https://doi.org/10.2337/dc09-S312

Burke, L. D. (1994). Premonolayer oxidation and its role in electrocatalysis. Electrochimica Acta, 39(12), 1841–1848. https://doi.org/10.1016/0013-4686(94)85173-5

Butterworth, A., Pratibha, P., Marx, A., & Corrigan, D. K. (2021). Electrochemical detection of oxacillin resistance using direct-labeling solid-phase isothermal amplification. ACS Sensors, 6(10), 3773–3780.
https://doi.org/10.1021/acssensors.1c01688

Clark, L. C., Jr., & Lyons, C. (1962). Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of Sciences, 102, 29–45. https://doi.org/10.1111/j.1749-6632.1962.tb13623.x

Csoregi, E., Schmidtke, D. W., & Heller, A. (1995). Design and optimization of a selective subcutaneously implantable glucose electrode based on wired glucose oxidase. Analytical Chemistry, 67(7), 1240–1244. https://doi.org/10.1021/ac00103a015

Gao, H., Soto, M. A., Szymkowiak, J. K., Andrew, L. J., Hamad, W. Y., & MacLachlan, M. J. (2023). Halloysite nanotubes enhance the mechanical properties and thermal stability of iridescent cellulose nanocrystal films. Dalton Transactions, 52(21), 7136–7142. https://doi.org/10.1039/D3DT00498H

Gao, Z.-D., Qu, Y., Li, T., Shrestha, N. K., & Song, Y.-Y. (2014). Development of amperometric glucose biosensor based on Prussian Blue functionalized TiO2 nanotube arrays. Scientific Reports, 4, 6891.
https://doi.org/10.1038/srep06891

Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000). Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technology & Therapeutics, 2(1), 49–56. https://doi.org/10.1089/152091500316737

Han, R., Sun, Y., Dai, Y., Gao, D., Wang, X., & Luo, C. (2021). A chemiluminescence aptasensor for sensitive detection of carcinoembryonic antigen based on dual aptamer-conjugates biorecognition. Sensors and Actuators B: Chemical, 326, 128833. https://doi.org/10.1016/j.snb.2020.128833

Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021). Recent advances in enzymatic and non-enzymatic electrochemical glucose sensing. Sensors, 21(14), 4672. https://doi.org/10.3390/s21144672

Huang, L., Zhao, H., Yi, T., Qi, M., Xu, H., Mo, Q., Huang, C., Wang, S., & Liu, Y. (2020). Preparation and properties of cassava residue cellulose nanofibril/cassava starch composite films. Nanomaterials, 10(4), 755.
https://doi.org/10.3390/nano10040755

Ju, J., Li, L., Regmi, S., Zhang, X., & Tang, S. (2022). Microneedle-based glucose sensor platform: From in vitro to wearable point-of-care testing systems. Biosensors, 12(8), 606. https://doi.org/10.3390/bios12080606

Khan, M. U., Rahman, M. M., Zahan, N., Masud, M. K., Sarker, S., & Haque, M. H. (2025). Electrochemical biosensing for antibiotic-resistant bacteria: Advances, challenges, and future directions. Micromachines, 16(9), 986.
https://doi.org/10.3390/mi16090986

Khan, R., Radoi, A., Rashid, S., Hayat, A., Vasilescu, A., & Andreescu, S. (2021). Two-dimensional nanostructures for electrochemical biosensor. Sensors, 21(10), 3369.
https://doi.org/10.3390/s21103369

Khor, S. M., Choi, J., Won, P., & Ko, S. H. (2022). Challenges and strategies in developing an enzymatic wearable sweat glucose biosensor as a practical point-of-care monitoring tool for type II diabetes. Nanomaterials, 12(2), 221. https://doi.org/10.3390/nano12020221

Kudlacik-Kramarczyk, S., Kieres, W., Przybylowicz, A., Ziejewska, C., Marczyk, J., & Krzan, M. (2025). Recent advances in micro- and nano-enhanced intravascular biosensors for real-time monitoring, early disease diagnosis, and drug therapy monitoring. Sensors, 25(15), 4855.
https://doi.org/10.3390/s25154855

Lee, S. J., Yoon, H. S., Xuan, X., Park, J. Y., Paik, S.-J., & Allen, M. G. (2016). A patch-type non-enzymatic biosensor based on 3D SUS microneedle electrode array for minimally invasive continuous glucose monitoring. Sensors and Actuators B: Chemical, 222, 1144–1151. https://doi.org/10.1016/j.snb.2015.08.013

Li, M., Xiao, M., Wang, Q., Zhang, J., Xue, X., Zhao, J., Zhang, W., & Lu, C. (2022). Mechanically strong and electrically conductive polyethylene oxide/few-layer graphene/cellulose nanofibrils nanocomposite films. Nanomaterials, 12(23), 4152. https://doi.org/10.3390/nano12234152

Liu, Y., Yu, Q., Luo, X., Yang, L., & Cui, Y. (2021). Continuous monitoring of diabetes with an integrated microneedle biosensing device through 3D printing. Microsystems & Nanoengineering, 7, 75. https://doi.org/10.1038/s41378-021-00302-w

Ma, J., Yang, S., Yang, Z., He, Z., & Du, Z. (2025). Functional nanomaterials for advanced bioelectrode interfaces: Recent advances in disease detection and metabolic monitoring. Sensors, 25(14), 4412.
https://doi.org/10.3390/s25144412

Matthews, D. R., Holman, R. R., Bown, E., Steemson, J., Watson, A., Hughes, S., & Scott, D. (1987). Pen-sized digital 30-second blood glucose meter. The Lancet, 1(8536), 778–779. https://doi.org/10.1016/S0140-6736(87)92802-9

Mohamad Nor, N., Ridhuan, N. S., & Abdul Razak, K. (2022). Progress of enzymatic and non-enzymatic electrochemical glucose biosensor based on nanomaterial-modified electrode. Biosensors, 12(12), 1136. https://doi.org/10.3390/bios12121136

Mohammadpour-Haratbar, A., Mohammadpour-Haratbar, S., Zare, Y., Rhee, K. Y., & Park, S.-J. (2022). A review on non-enzymatic electrochemical biosensors of glucose using carbon nanofiber nanocomposites. Biosensors, 12(11), 1004.
https://doi.org/10.3390/bios12111004

Moura, P. C., Ribeiro, P. A., Raposo, M., & Vassilenko, V. (2023). The state of the art on graphene-based sensors for human health monitoring through breath biomarkers. Sensors, 23(22), 9271.
https://doi.org/10.3390/s23229271

Norouz Dizaji, A., Ali, Z., Ghorbanpoor, H., Ozturk, Y., Akcakoca, I., Avci, H., & Dogan Guzel, F. (2021). Electrochemical-based “antibiot-sensor” for the whole-cell detection of vancomycin-susceptible bacteria. Talanta, 234, 122695.
https://doi.org/10.1016/j.talanta.2021.122695

Ortiz, M., Jauset-Rubio, M., Skouridou, V., Machado, D., Viveiros, M., Clark, T. G., Simonova, A., Kodr, D., Hocek, M., & O’Sullivan, C. K. (2021). Electrochemical detection of single-nucleotide polymorphism associated with rifampicin resistance in Mycobacterium tuberculosis using solid-phase primer elongation with ferrocene-linked redox-labeled nucleotides. ACS Sensors, 6(12), 4398–4407. https://doi.org/10.1021/acssensors.1c01710

Osuna, V., Vega-Rios, A., Zaragoza-Contreras, E. A., Estrada-Moreno, I. A., & Dominguez, R. B. (2022). Progress of polyaniline glucose sensors for diabetes mellitus management utilizing enzymatic and non-enzymatic detection. Biosensors, 12(3), 137. https://doi.org/10.3390/bios12030137

Otero, F., & Magner, E. (2020). Biosensors—Recent advances and future challenges in electrode materials. Sensors, 20(12), 3561. https://doi.org/10.3390/s20123561

Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022). Glucose biosensors in clinical practice: Principles, limits and perspectives of currently used devices. Theranostics, 12, 493–511.
https://doi.org/10.7150/thno.64035

Ramezani, G., Stiharu, I., van de Ven, T. G. M., & Nerguizian, V. (2024). Advancements in hybrid cellulose-based films: Innovations and applications in 2D nano-delivery systems. Journal of Functional Biomaterials, 15(4), 93. https://doi.org/10.3390/jfb15040093

Rao, L. V., Jakubiak, F., Sidwell, J. S., Winkelman, J. W., & Snyder, M. L. (2005). Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction. Clinica Chimica Acta, 356(1–2), 178–183. https://doi.org/10.1016/j.cccn.2005.01.027

Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010). Electrochemical biosensors. Chemical Society Reviews, 39(5), 1747–1763. https://doi.org/10.1039/b714449k

Shichiri, M., Kawamori, R., Yamasaki, Y., Hakui, N., & Abe, H. (1982). Wearable artificial endocrine pancreas with needle-type glucose sensor. The Lancet, 2(8308), 1129–1131. https://doi.org/10.1016/S0140-6736(82)92788-X

Stratton, I. M., Adler, A. I., Neil, H. A., Matthews, D. R., Manley, S. E., Cull, C. A., … Holman, R. R. (2000). Association of glycaemia with macrovascular and microvascular complications of type 2 diabetes (UKPDS 35). BMJ, 321(7258), 405–412. https://doi.org/10.1136/bmj.321.7258.405

Szymanska, B., Lukaszewski, Z., Zelazowska-Rutkowska, B., Hermanowicz-Szamatowicz, K., & Gorodkiewicz, E. (2021). An SPRi biosensor for determination of the ovarian cancer marker HE4 in human plasma. Sensors, 21(10), 3567. https://doi.org/10.3390/s21103567

The Diabetes Control and Complications Trial Research Group. (1993). The effect of intensive treatment of diabetes on long-term complications in insulin-dependent diabetes mellitus. New England Journal of Medicine, 329(14), 977–986. https://doi.org/10.1056/NEJM199309303291401

Turner, A. P. F. (2000). Biosensors—Sense and sensibility. Science, 290(5495), 1315–1317. https://doi.org/10.1126/science.290.5495.1315

Updike, S. J., & Hicks, G. P. (1967). The enzyme electrode. Nature, 214(5092), 986–988.
https://doi.org/10.1038/214986a0

Ventrelli, L., Marsilio Strambini, L., & Barillaro, G. (2015). Microneedles for transdermal biosensing: Current picture and future direction. Advanced Healthcare Materials, 4(17), 2606–2640.
https://doi.org/10.1002/adhm.201500450

Vesper, H. W., & Myers, G. L. (2007). Approaches for improving glucose monitor measurements: From measurement harmonization to external quality assessment programs. Journal of Diabetes Science and Technology, 1(1), 153–157. https://doi.org/10.1177/193229680700100202

Wang, J., Zhu, C.-K., Yu, J.-Q., Tan, R., & Yang, P.-L. (2021). Hypoglycemia and mortality in sepsis patients: A systematic review and meta-analysis. Heart & Lung, 50(6), 933–940. https://doi.org/10.1016/j.hrtlng.2021.07.017

Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., … Cao, S. (2021). Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid. Nature Biomedical Engineering, 5(1), 64–76.
https://doi.org/10.1038/s41551-020-00672-y

Wu, Y., Wang, C., Wang, C., Wang, P., Chang, X., Han, L., & Zhang, Y. (2022). Multiple biomarker simultaneous detection in serum via a nanomaterial-functionalized biosensor for ovarian tumor/cancer diagnosis. Micromachines, 13(12), 2046. https://doi.org/10.3390/mi13122046

Yoo, E.-H., & Lee, S.-Y. (2010). Glucose biosensors: An overview of use in clinical practice. Sensors, 10(5), 4558–4576. https://doi.org/10.3390/s100504558

Zhao, L., Wen, Z., Jiang, F., Zheng, Z., & Lu, S. (2020). Silk/polyols/glucose oxidase microneedle-based electrochemical biosensor for continuous glucose monitoring. RSC Advances, 10, 6163–6171. https://doi.org/10.1039/C9RA10374K

Zhu, J., Liu, X., Wang, X., Huo, X., & Yan, R. (2015). Preparation of polyaniline-TiO2 nanotube composite for electrochemical biosensors. Sensors and Actuators B: Chemical, 221, 450–457. https://doi.org/10.1016/j.snb.2015.06.131

Zhu, J., Zhou, X., Kim, H. J., Qu, M., Jiang, X., Lee, K., … Zhu, X. (2020). Gelatin methacryloyl microneedle patches for minimally invasive extraction of interstitial fluid. Small, 16(10), 1905910. https://doi.org/10.1002/smll.201905910


Article metrics
View details
0
Downloads
0
Citations
30
Views

View Dimensions


View Plumx


View Altmetric



0
Save
0
Citation
30
View
0
Share